( TF09E8YA46500056901NAAT00 )


Starter

Item
Measurement
Qualification
Standard or New
Service Limit
Starter
Output
Except L13Z1 (M/T), L13Z3 (M/T), L15A8 (M/T)
0.7 kW
L13Z1 (M/T), L13Z3 (M/T), L15A8 (M/T)
0.6 kW
Commutator mica depth
0.45−0.75 mm (0.018−0.030 in.)
0.20 mm (0.008 in.)
Commutator runout
0.05 mm (0.002 in.) max.
0.4 mm (0.02 in.)
Commutator O.D.
27.9−28.0 mm (1.098−1.102 in.)
27.0 mm (1.06 in.)
Brush length
9.7−10.3 mm (0.38−0.41 in.)
6.0 mm (0.20 in.)