N2
|
BLK
|
Under all conditions
|
Check for continuity to ground: There should be continuity.
|
-
Poor ground (G501)
-
An open in the wire
|
K10
|
BLK
|
Under all conditions
|
Check for continuity to ground: There should be continuity.
|
-
Poor ground (G502)
-
An open in the wire
|
Q9
|
BLK
|
Under all conditions
|
Check for continuity to ground: There should be continuity.
|
-
Poor ground (G502)
-
An open in the wire
|
M16
|
BLK
|
Under all conditions
|
Check for continuity to ground: There should be continuity.
|
-
Poor ground (G501)
-
An open in the wire
|
M14
|
BLK
|
Under all conditions
|
Check for continuity to ground: There should be continuity.
|
-
Poor ground (G501)
-
An open in the wire
|
Q2
|
BLU
|
Under all conditions
|
Check for continuity between the Q2 terminal and the data link connector (16P) connector No. 7 terminal: There should be continuity.
|
An open in the wire
|
Check for continuity to ground: There should be no continuity.
|
A short to ground in the wire
|
Q2
|
BLU
|
Immobilizer-keyless control unit 7P connector disconnected
|
Check for continuity between the Q2 terminal and the immobilizer-keyless control unit 7P connector No. 5 terminal: There should be continuity.
|
An open in the wire
|
Check for continuity to ground: There should be no continuity.
|
A short to ground in the wire
|
Q2
|
BLU
|
Audio unit connector A (24P) disconnected
|
Check for continuity between the Q2 terminal and audio unit connector A (24P) No. 3 terminal: There should be continuity.
|
An open in the wire
|
Check for continuity to ground: There should be no continuity.
|
A short to ground in the wire
|
Q2
|
BLU
|
SRS unit connector A (39P) disconnected
|
Check for continuity between the Q2 terminal and SRS unit connector A (39P) No. 18 terminal: There should be continuity.
|
An open in the wire
|
Check for continuity to ground: There should be no continuity.
|
A short to ground in the wire
|
Q2
|
BLU
|
ABS modulator-control unit 25P connector disconnected
|
Check for continuity between the Q2 terminal and the ABS modulator-control unit 25P connector No. 10 terminal: There should be continuity.
|
An open in the wire
|
Check for continuity to ground: There should be no continuity.
|
A short to ground in the wire
|
Q2
|
BLU
|
EPS control unit connector C(16P) disconnected
|
Check for continuity between the Q2 terminal and EPS control unit connector C (16P) No. 16 terminal: There should be continuity.
|
An open in the wire
|
Check for continuity to ground: There should be no continuity.
|
A short to ground in the wire
|
Q3
|
GRN [LT GRN]
|
Immobilizer-keyless control unit 7P connector disconnected
|
Check for continuity between the Q3 terminal and the immobilizer-keyless control unit 7P connector No. 4 terminal: There should be continuity.
|
An open in the wire
|
Check for continuity to ground: There should be no continuity.
|
A short to ground in the wire
|
Q3
|
GRN [LT GRN]
|
Gauge control module 32P connector disconnected
|
Check for continuity between the Q3 terminal and the gauge control module 32P connector No. 18 terminal: There should be continuity.
|
An open in the wire
|
Check for continuity to ground: There should be no continuity.
|
A short to ground in the wire
|