Heating and A/C Symptom Troubleshooting Index

Symptom
Diagnostic procedure
Also check for
Recirculation control doors do not change between Fresh and Recirculate
  • Blown fuse No. 10 (7.5 A) in the under-dash fuse/relay box
  • Cleanliness and tightness of all terminals
Heater controls, and A/C do not work
  • Blown fuse No. 10 (7.5 A) in the under-dash fuse/relay box
  • Poor ground at G502
  • Cleanliness and tightness of all terminals
Blower motor runs, but one or more speeds are inoperative
Cleanliness and tightness of all connectors
Blower motor does not run at all
  • Blown fuse No. 10 (7.5 A) and No. 57 (30 A) in the under-dash fuse/relay box
  • Poor ground at G501
  • Cleanliness and tightness of all connectors
A/C condenser fan does not run at all (but radiator fan runs with the A/C on)
  • Blown fuse No. 47 (30 A) in the under-dash fuse/relay box
  • Poor ground at G202
  • Cleanliness and tightness of all connectors
Both fans do not run with the A/C on (but the A/C compressor runs with the A/C on)
  • Blown fuse No. 30 (30 A) and No. 47 (30 A) in the under-dash fuse/relay box
  • Poor ground at G202
  • Cleanliness and tightness of all connectors
A/C compressor clutch does not engage (but both fans run with the A/C on)
  • Blown fuse No. 43 (7.5 A) in the under-dash fuse/relay box
  • Cleanliness and tightness of all connectors
A/C system does not come on (both fans and the A/C compressor do not work); heater is OK
  • Poor ground at G502
  • Cleanliness and tightness of all connectors