Remove the bolts, O-rings (A) and the expansion valve (B) from the pipe (C).
-
Install the expansion valve in the reverse order of removal, and note these items:
-
Replace the O-rings with new ones at each fitting, and apply a thin coat of refrigerant oil before installing them. Be sure to use the correct O-rings for HFC-134a (R-134a) to avoid leakage.
-
Immediately after using the oil, reinstall the cap on the container, and seal it to avoid moisture absorption.
-
Do not spill the refrigerant oil on the vehicle; it may damage the paint; if the refrigerant oil contacts the paint, wash it off immediately.
-
Make sure that there is no air leakage.
-
|
LHD model
RHD model
|