Symptom
|
Diagnostic procedure
|
|
---|---|---|
Motor noise from sunshade
|
1.
2.
3.
4.
|
Check for a loose motor.
Check for a worn gear or bearing.
Check for a deformed cable assembly.
Check for dirt or debris.
|
Sunshade does not move, but motor turns
|
1.
2.
3.
4.
5.
|
Check for foreign matter stuck between the guide rail and the slider.
Make sure the cable assembly is attached properly.
Check for a loose inner cable.
Check for a defective gear or inner cable.
Check for a connect shoe.
|
Sunshade does not move and motor does not turn (sunshade can be moved with 4 mm hexagonal wrench)
|
1.
2.
3.
4.
|
Check for a run down battery.
Check for a blown fuse.
Check for a faulty sunshade switch.
Check for a defective motor control unit.
|
Sunshade does not stop at proper flush closed position
|
||
Sunshade moves in a jerking motion (moves 40 mm (1.57 in.), stops for 0.4 seconds, and repeats)
|
||
During auto close operation, sunshade reverses when no object is trapped
|
1.
2.
|
|
Sunshade moves, but there is no AUTO function
|