Measure the clearance between change lever (A) and the select lever (B) with a feeler gauge (C). If the clearance is more than the service limit, go to
Step 2
.
Standard:
0.05−0.35 mm (0.002−0.014 in.)
Service Limit:
0.55 mm (0.022 in.)
Measure the groove width of the change lever.
If distance is not within the standard, replace the change lever with a new one.