DTC P19F6:
Select Actuator Motor Position Sensor Ground Line Open
-
Turn the ignition switch to ON (II).
-
Clear the DTCs with the HDS.
-
Turn the ignition switch to LOCK (0).
-
Turn the ignition switch to ON (II).
-
Check for DTCs with the HDS.
YES
|
-
|
|
NO
|
-
|
Intermittent failure, the system is OK at this time.■
|
-
Turn the ignition switch to LOCK (0).
-
Disconnect the select actuator motor 6P connector.
-
Disconnect the change actuator subharness B 10P connector.
-
Check for continuity between change actuator subharness B 10P connector terminal No. 8 and select actuator motor 6P connector terminal No. 2.
YES
|
-
|
|
NO
|
-
|
Repair an open in the wire of the change actuator subharness B.■
|
|