DTC P19F2:
Shift Actuator Motor Rotating Direction Sensor Signal Circuit High Voltage
-
Turn the ignition switch to ON (II).
-
Clear the DTCs with the HDS.
-
Turn the ignition switch to LOCK (0).
-
Turn the ignition switch to ON (II).
-
Check for DTCs with the HDS.
YES
|
-
|
|
NO
|
-
|
Intermittent failure, the system is OK at this time.■
|
-
Turn the ignition switch to LOCK (0).
-
Disconnect the shift actuator motor 6P connector.
-
Connect shift actuator motor 6P connector terminal No. 4 and body ground with a jumper wire.
-
Turn the ignition switch to ON (II).
-
Clear the DTCs with the HDS.
-
Turn the ignition switch to LOCK (0).
-
Turn the ignition switch to ON (II).
-
Check for DTCs with the HDS.
YES
|
-
|
Repair an open in the wire between the TCM (B8) and the shift actuator motor.■
|
NO
|
-
|
|
-
Turn the ignition switch to LOCK (0).
-
-
Disconnect the TCM connector B (40P).
-
Turn the ignition switch to ON (II).
|