DTC P19EF:
Shift Actuator Motor Position Sensor Ground Line Open
-
Turn the ignition switch to ON (II).
-
Clear the DTCs with the HDS.
-
Turn the ignition switch to LOCK (0).
-
Turn the ignition switch to ON (II).
-
Check for DTCs with the HDS.
YES
|
-
|
|
NO
|
-
|
Intermittent failure, the system is OK at this time.■
|
-
Turn the ignition switch to LOCK (0).
-
Disconnect the shift actuator motor 6P connector.
-
-
Disconnect TCM connector B (40P).
-
Check for continuity between TCM connector terminal B1 and shift actuator motor 6P connector terminal No. 2.
YES
|
-
|
|
NO
|
-
|
Repair an open in the wire of the change actuator subharness A.■
|
|