NOTE: If replacement is required, always replace the synchro sleeve and hub as a set.
-
Support the bearing inner race with an appropriate sized socket (A), and push down on the mainshaft (B).
-
Measure the clearance between 2nd (C) and 3rd (D) gears with a feeler gauge (E).
-
If the clearance is more than the service limit, go to
Step 3
.
-
If the clearance is within the service limit, go to
Step 4
.
Standard:
|
0.06−0.21 mm (0.002−0.008 in.)
|
Service Limit:
|
0.30 mm (0.012 in.)
|
|