M/T Shift Arm Clearance Inspection

  1. Measure the clearance between the shift arm (A) and shift piece (B) with a feeler gauge (C). If the clearance exceeds the service limit, go to Step 2 .
    Standard:
    0.20−0.60 mm (0.008−0.024 in.)
    Service Limit:
    0.7 mm (0.028 in.)


  1. Measure the diameter of the shift piece.
    • If the diameter is not within the standard, replace the shift piece.
    • If the diameter is within the standard, replace the shift arm.
    Standard:
    16.00−16.20 mm (0.630−0.638 in.)