( TF09E1TE10480157001NAAT00 )


Stator shaft

Item
Measurement
Qualification
Standard or New
Service Limit
Stator shaft
Needle bearing contact I.D.
Torque converter side
27.000−27.021 mm (1.063−1.064 in.)
When worn or damaged
ATF pump side
29.000−29.021 mm (1.1417−1.1426 in.)
———
Sealing ring contact area I.D.
29.000−29.021 mm (1.1417−1.1426 in.)
29.05 mm (1.144 in.)