( TF09E1TE10410900000NAAT00 )


Countershaft

Item
Measurement
Qualification
Standard or New
Service Limit
Countershaft
Diameter of needle bearing contact area
At torque converter housing
33.504−33.517 mm (1.3191−1.3196 in.)
When worn or damaged
At 5th gear
32.986−32.999 mm (1.2987−1.2991 in.)
When worn or damaged
Reverse selector hub
35.983−35.999 mm (1.4167−1.4173 in.)
When worn or damaged
I.D. of gears
5th gear
39.000−39.016 mm (1.5354−1.5361 in.)
When worn or damaged
Reverse gear
42.000−42.016 mm (1.6535−1.6542 in.)
When worn or damaged
End play
5th gear
0.04−0.27 mm (0.002−0.011 in.)
———
Reverse gear
0.10−0.25 mm (0.004−0.010 in.)
———
Reverse selector hub width
29.25−29.45 mm (1.152−1.160 in.)
———
Collar, 33.2 x 40 x 26 mm length
25.95−26.00 mm (1.022−1.024 in.)
———
Reverse selector hub O.D.
51.87−51.90 mm (2.042−2.043 in.)
When worn or damaged