DTC B1906:
Immobilizer-Keyless Control Unit Lost Communication with Gauge Control Module (A/T Message)
-
Clear the DTCs with the HDS.
-
Turn the ignition switch to LOCK (0), and then back to ON (II).
-
Wait for 6 seconds or more.
-
Check for DTCs with the HDS.
YES
|
-
|
|
NO
|
-
|
Intermittent failure, the system is OK at this time. Check for loose or poor connections between the gauge control module and the immobilizer-keyless control unit.■
|
-
Turn the ignition switch to LOCK (0).
-
Connect the HDS to the data link connector, then turn the ignition switch to ON (II).
-
Select the BODY ELECTRICAL menu, then enter the UNIT INFORMATION.
-
Check the condition of the gauge control module from the CONNECTED UNIT list.
Is NOT AVAILABLE indicated?
|
-
YES
|
-
|
|
NO
|
-
|
Repair the faulty input, then recheck the DTCs.■
|
-
Turn the ignition switch to LOCK (0).
-
Disconnect the gauge control module 32P connector.
-
Turn the ignition switch to ON (II).
-
Measure the voltage between the gauge control module 32P connector No. 16 and No. 32 terminals and body ground.
Is there battery voltage?
|
YES
|
-
|
|
NO
|
-
|
Check the No. 1 (10 A) and the No. 20 (15 A) fuses in the under-dash fuse/relay box. If the fuse is blown, replace the fuse and recheck the DTCs. If the fuses are OK, repair an open in the wire between the under-dash fuse/relay box and the gauge control module.■
|
-
Turn the ignition switch to LOCK (0).
|