Replace the thermostat if it is open at room temperature.
To test a closed thermostat:
-
Suspend the thermostat (A) in a container of water. Do not let the thermometer (B) touch the bottom of the hot container.
-
Heat the water, and check the temperature with a thermometer. Check the temperature where the thermostat first opens, and where it is fully open.
-
Measure the lift height of the thermostat when it is fully open.
Standard Thermostat
Lift Height:
|
Above 8.0 mm (0.31 in.)
|
Starts Opening:
|
76−80 °C (169−176 °F)
|
Fully Open:
|
90 °C (194 °F)
|
|