DTC 5: | An Open in the Sunlight Sensor Circuit |
1. | Disconnect the sunlight sensor 2P connector. |
2. | Disconnect climate control unit connectors A (12P) and B (16P). |
3. | Check for continuity between the No. 9 terminal of climate control unit connector A (12P) and the No. 1 terminal of the sunlight sensor 2P connector.
Is there continuity? YES - Go to 4. NO - Repair open in the wire between the climate control unit and the sunlight sensor.n |
4. | Check for continuity between the No. 5 terminal of climate control unit connector B (16P) and the No. 2 terminal of the sunlight sensor 2P connector.
Is there continuity? YES - Go to 5. NO - Repair open in the wire between the climate control unit and the sunlight sensor.n |
5. | Reconnect the sunlight sensor 2P connector. |
6. | Reconnect climate control unit connectors A (12A) and B (16P). |
7. | Test the sunlight sensor. Is the sunlight sensor OK? YES - Check for loose wires or poor connections at climate control unit connectors A (12P) and B (16P) and at the sunlight sensor 2P connector. If the connections are good, substitute a known-good climate control unit, and recheck. If the symptom/indication goes away, replace the original climate control unit.n NO - Replace the sunlight sensor.n |