1. | Disconnect the 7P connector from the mode control motor. |
2. | Connect battery power to the No. 1 terminal of the mode control motor, and ground the No. 2 terminal; the mode control motor should run smoothly, and stop at Vent. If it doesn't, reverse the connections; the mode control motor should run smoothly, and stop at Defrost. When the mode control motor stops running, disconnect battery power immediately.
|
3. | If the mode control motor does not run in 2, remove it, then check the mode control linkage and doors for smooth movement.
|
4. | Use a digital multimeter with an output of 1 mA or less at the 20 kW range. With the mode control motor running as in 2, check for continuity between the No. 3, 4, 5, and 6 terminals and the No. 7 terminal individually. There should be continuity for a moment at each terminal. |
5. | If there is no continuity for a moment at each terminal, replace the mode control motor. |