Symptom | Diagnostic procedure | Also check for |
---|---|---|
The blower motor does not run immediately even th ough the engine is fully warmed up NOTE: The temperature control dial must be set between 18°C (64°F) and 32°C (90°F) | ECT Sensor Circuit Troubleshooting | Cleanliness and tightness of all connectors |
Both heater and A/C do not work | Climate Control Power and Ground Circuits Troubleshooting |
|
Condenser fan does not run at all (but radiator fan runs with the A/C on) | Condenser Fan Circuit Troubleshooting |
|
Both fans do not run with the A/C on | Radiator and Condenser Fans Common Circuit Troubleshooting |
|
Compressor clutch does not engage | Compressor Clutch Circuit Troubleshooting |
|
A/C System does not come on (both fans and compressor) | A/C Pressure Switch Circuit Troubleshooting | Cleanliness and tightness of all connectors |