Measure the clearance between reverse idler gear (A) and the reverse shift fork (B) with a feeler gauge (C). If the clearance is more than the service limit, go to 2.
Standard:
1.30 - 1.90 mm (0.051 - 0.075 in.)
Service Limit:
2.5 mm (0.098 in.)
2.
Measure the width of the reverse shift fork.
If distance is not within the standard, replace the reverse shift fork with a new one.
If distance is within the standard, replace the reverse idler gear with a new one.