Starter Solenoid Test
Starter Solenoid Test
1.
Check the hold-in coil for continuity between the S terminal (A) and the armature housing (ground). There should be continuity.
If there is continuity, go to
2
.
If there is no continuity, replace the solenoid.
2.
Check the pull-in coil for continuity between the S terminal (A) and M terminal (B). There should be continuity.
If there is continuity, the solenoid is OK.